PHARMACEUTICALS STUDIES
▼
Tuesday, 4 July 2017

General Testing Procedure For PVC PACKING MATERIAL

›
    1.       Description: PVC film of specification: - Non toxic transparent /nontransparent PVC. It shall be free from foreign matter, p...
2 comments:

General Testing Procedure For Printed Aluminium Blister Foil

›
Description: An Aluminium Blister foil printed with text matter as per approved artwork and colour scheme. Width: Take a sample of 1...
12 comments:
Monday, 10 April 2017

General Test Procedure For Oxidisable Substance

›
PROCEDURE  To 100 ml of sample in 250 ml conical flask, add 10 ml of dilute sulfuric acid and 0.1 ml of 0.02M potassium permanganate and ...

Preparation of Nitrate standard Solution (100ppm) for limit Test

›
PROCEDURE: Dissolve and dilute 0.163 g of potassium nitrate to 100ml with water. Dilute 1 volume of above solution to 10 volumes with wa...

Preparation of Nitrate Standard Solution (2ppm) for Limit Test

›
PROCEDURE: Dissolve and dilute 0.163 g of potassium nitrate to 100ml with water. Dilute 1 volume of above solution to 10 volumes...

Preparation of Lead Nitrate Stock Solution (1000ppm) for Limit Test

›
PROCEDURE: Dissolve 0.4gm of Lead nitrate in water containing 2ml of nitric acid and add sufficient water to     produce 250.0ml.

Preparation of Iron Standard Solution (10ppm) for Limit Test

›
PROCEDURE: Dissolve 7.022 g of ferrous ammonium sulphate in water containing 25 ml of 1M sulphuric acid and add sufficient water to pro...

Preparation of Chloride Standard Solution (25ppm) for Limit Test

›
PROCEDURE: Dilute 5 volumes of a 0.0824 % w/v solution of sodium chloride to 100 volumes with water.
1 comment:

Preaparation of Arsenic Standard Solution (10ppm) for Limit Test

›
PROCEDURE: Dissolve 0.33 g of arsenic trioxide in 5 ml of 2M sodium hydroxide and dilute to 250.0ml with         water. Dilute 1 Volume...

Preaparation of Ammonium standard Solution (1ppm) For Limit Test

›
PROCEDURE Dilute 10.0 ml of a 0.0741% w/v solution of ammonium chloride to 25.0 ml with ammonia-free     water. Dilute 1 Volume of the r...

Preaparation of Lead Standard Solution (1ppm) For Limit Test

›
PROCEDURE: Dilute 1 volume of lead standard solution (0.1 % Pb) to 10 volume with water (i.e.100 ppm  Pb), Dilute 1 volume of lead stand...
Thursday, 9 March 2017

Operating and temperature monitoring of incubator/BOD incubator

›
1.0       Objective      To lay down a procedure cleaning, operating and temperature monitoring of incubator/BOD incubator.       2.0 ...
1 comment:

Microbial analysis of oral suspension.

›
      1.0       Objective      To lay down a procedure for microbial analysis of oral suspension.       2.0        Responsibility   ...

microbial analysis of Hard gelatin capsule and tablets.

›
      1.0       Objective      To lay down a procedure for microbial analysis of Hard gelatin capsule and tablets.   ...
›